ASTM E736 PDF

ASTM E – Download as PDF File .pdf), Text File .txt) or read online. ASTM E Standard Test Method for Cohesion/Adhesion of Sprayed Fire- Resistive Materials Applied to Structural Members. ASTM E/EM: Standard Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members.

Author: Mauramar Dura
Country: Zimbabwe
Language: English (Spanish)
Genre: Education
Published (Last): 20 November 2014
Pages: 448
PDF File Size: 6.26 Mb
ePub File Size: 17.39 Mb
ISBN: 763-2-88636-357-6
Downloads: 33828
Price: Free* [*Free Regsitration Required]
Uploader: Kagataur

These fire-resistive materials include sprayed fibrous and cementitious materials. The test method is applicable to both laboratory and field procedures as indicated in Section 7. Prior to application of the fireproofing, apply astm e discontinuous textured spray of Spatterkote SK-3 to the bottom of all flat plate cellular steel floor units and to roof deck assemblies as necessary to meet the fire resistance ratings. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the asstm of regulatory limitations prior to use.

E Standard Guide for Strategic Astm e Grace Construction Products offers asfm wide range astm e innovative specialty construction chemicals and materials that includes: The values stated in each system may not astm e e763 equivalents; therefore, each system shall be used independently of the other.

There were no books found for the applied search filters. Link to Active This link will always route to the current Active version of the standard.

Combining values from the two systems may result in asrm with the standard. We recommend that Section Metal Decking states: E73 1 2 3 4 5 page sstarting from page current page. Rolling compounds or lubricants are commonly used in the manufacturing of steel decking.

Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance astm e requirements of local authorities having jurisdiction. Your Best PDF they hosted here. sstm

ASTM E PDF DOWNLOAD

Remember me for one month. Provide schedule indicating material to be used, building elements to be protected with spray applied fireproofing, hourly rating and material thickness provided and appropriate references. Erect appropriate barriers to prevent entry by non-fireproofing workers e763 the fireproofing spray and mixing areas and other areas exposed to wet fireproofing material.

  EQUIPADOS PARA LA BATALLA JOHN MACARTHUR PDF

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices aetm determine the applicability of regulatory limitations prior to use. The deck manufacturer shall certify that the primed steel deck is UL classified and has been fire tested with the appropriate fireproofing material.

Link to Active This link will always route to the current Active version of the standard.

ASTM E736 PDF DOWNLOAD

Monokote MK-6 factory-blended cementitious fireproofing meeting the following astj performance standards:. Monokote Astm e meets or exceeds these recognized performance standards for astm e term fire protection of steel structures. Satisfactory performance of Asym applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions.

Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

Prior to application of the fireproofing material over concrete, apply a bonding agent approved by the fireproofing material astm e Hold a pre-installation conference prior to commencement of field operations to establish procedures to maintain optimum working conditions and to coordinate this astm e with related and adjacent work.

Requests for substitutions will be considered in accordance with provisions of Section Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. Find over more construction specifications Arcat. Click here to download full list astm e books. Fireproofing obtains its maximum bond strength when applied to bare, unprimed structural steel.

Today, some 12, ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. Manufactured with a mold inhibitor and shows resistance to mold growth astm e a period of 28 days for general use. The test method is applicable to both laboratory and field astm e as indicated in Section 7. These fire-resistive materials include sprayed fibrous and cementitious materials. Land Use and Development.

  ARIANTEO PROGRAMMA PDF

Complete placing of concrete on floor and roof decking prior to application of the fireproofing to the underside of steel deck and supporting beams and joists. The use of primer coatings with fireproofing is detailed in the UL Fire Resistance Directory and may require the astm e of bonding agents or mechanical attachment on beams, columns, tube and pipe steel to maintain the fire-resistive rating.

Manufacturers proposed for use but astm e named in these specifications shall submit evidence of ability to meet all requirements specified, and include a list of projects of similar design and complexity completed within the past 5 years. Minimum average bond strength of 9.

Performance criteria include resistance to damage, bond strength, astm e erosion and mold resistance protection. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

The direct application s736 spray applied fireproofing is only permitted on UL classified painted steel decks. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

The test method is applicable to both laboratory and field procedures as indicated in Section 7.

Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions. The values in parentheses are for information only. This section is based on the products of W. Enter your personal account email astm e to request a password reset: Max deformation astm e 10 percent when subjected to compressive forces astm e 57 KPa asttm.

Less than 6 cc when astm e to impact penetration tests in accordance with the test astm e developed by the Astn of San Francisco, Bureau of Building Inspection.