ASTM D429 PDF

ASTM D determines the adhesion strength of rubber to rigid materials, such as metals. The standard requires that the testing machine conform to practices. This standard is issued under the fixed designation D ; the 1 These test methods are under the jurisdiction of ASTM Committee D11 on. This standard is issued under the fixed designation D ; the number These test methods are under the jurisdiction of ASTM Committee D11 on For.

Author: Dom Golkree
Country: Belize
Language: English (Spanish)
Genre: Literature
Published (Last): 8 April 2006
Pages: 232
PDF File Size: 15.16 Mb
ePub File Size: 17.35 Mb
ISBN: 947-7-57650-303-1
Downloads: 68157
Price: Free* [*Free Regsitration Required]
Uploader: Vijinn

Load ratings from 1 kN to 10 kN lbf to 2, lbf Maximum specimen thicknesses of 7 mm or 8 mm 0. Pneumatic grips are active in that they maintain the same gripping force even as the specimen necks down.

We use cookies to improve your browsing experience. Rubber is typically bonded to metal during the vulcanizing or heating process, but this method is for glue or other materials that are used after the rubber is made via vulcanizing.

Prepare the rubber specimen for this test by vulcanizing it to the metal material of the tank. The test engineer can learn more about the uniformity of the rubber coating from this visual monitoring. The test is an orthogonal tensile test where the puck is pulled apart in tension. Record the total load at the time of failure. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience. To begin testing, place the test specimen in the jaws attached to x429 fixed grip with the separating edge toward the operator.

Peel force is indicated in pounds per square inch of length of the peel line. Clamp force up to 1. Slippage in grips will be a big challenge in testing rubber coating of metal because coating adhesion must be strong but rubber material necks down, also called Poisson effect. Most of the tests involve orthogonal tensile strength or peel strength of the adhesion interface.

  CREATIVE AND MENTAL GROWTH VIKTOR LOWENFELD PDF

Some of the tests are aimed at shear strength of that adhesion interface. We are confident that we have what you are looking for. Method B describes a peel procedure to determine the adhesive strength ashm rubber materials to a metal plate or substrate. Loads as high at 10, pounds can be common.

Each puck should be. Please confirm that you agree with our privacy and cookies policy to submit this form. Screw side-action grips provide a very simple and efficient method for holding test specimens in a wide range of applications.

Email addresses can only contain letters, numbers and the following special characters: Email addresses can only contain letters, numbers and the following special characters: Forces up to 10 kN 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more. The data obtained indicate the strength of v429 along a line across the width of the rubber strip being separated from a metal plate at a 90 degree angle.

This test machine is suggested because it has a long travel, which is preferred because rubber coating tests to enlongate quite a bit when stretched. Either the rubber material d492 internally or at the adhesion surface to the metal. Place your specimens in the tensile test machines and pull to failure each test piece which remains sufficiently intact, including those exposed to the chosen environmental conditions and the control test pieces, and record the peak force required to do this.

Maintaining unidirectional force throughout the process of peeling from a astmm.

Next, the test pieces should be pre-strained by pulling in a test machine to just above the desired pre-strain and inserting a nylon block between the central metal plates to maintain the prescribed prestrain. Concrete, Asphalt and Rock. The assembly is cured in a degree Celcius oven for one hour. Each specimen will consist of a rubber puck with 2 pieces of metal.

It is important to review ASTM D in order to fully understand the test setup, procedure, and results requirements.

  100 RECETAS HERMANA BERNARDA PDF

Works very well with flat, thin specimens Eccentric design increases gripping force with tension. Next, place the specimen in the jaws attached to the fixed grip with the separating edge toward the operator. The ASTM D standard describes methods to perform these tests with deadweights as an alternative to using a test machine.

We highly recommend not using deadweights as those are outdated methods of retrieving data. Pneumatic grips also provide constant clamping force throughout the test to avoid specimen slippage. It is important to review ASTM D in order to fully understand the test setup, procedure, and results requirements.

Pneumatic grips also provide constant clamping force throughout the test to avoid specimen slippage. Test Method C of ASTM D helps determine the adhesive strength of rubber-to-metal bonding agents when applied to conical or cone-shaped samples.

ASTM D Rubber Property – Adhesion to Rigid Substrates – Instron

They are designed with standard and optional features that increase testing efficiency and improve the testing experience for the operator. Maintaining unidirectional force throughout the process of peeling from a substrate.

Line contact and special coated faces are also available. Method H is used for determining relative bond durability between adhesives with a quadruple shear test.

They can be equipped with a selection of interchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated.

We also recommend serrated jaws on your grips to avoid sample slipping.

ASTM D429 Rubber to Metal Adhesion Test Equipment

Manual vice grips may also work but must be tightened very tight. The challenges of testing to this standard: The test machine should be equipped with swivel joints above and below to ensure uniformly distributed tensile force tensile force through the specimen assembly.

The bonded area is 25mm by 25mm in the middle of the metal piece.